Do-it-yourself construction and repairs

ZONT - H Thermostats for remote control of the boiler. Smart thermostat Zont GSM-Climate H1 - monitoring room temperature, remote control of the heating boiler, fault notification, Internet service Inputs, outputs and connections

Remote control unit for boiler ZONT H-1 GSM-Climate

  • Supply voltage 10-14 V
  • Maximum current consumption 150 mA
  • Maximum current through relay contacts 1000 mA
  • GSM modem frequency ranges 800, 900, 1800, 1900 MHz
  • Weight: 200 g

ZONT H-1 GSM-Climate is a modern device for controlling a heating boiler via the Internet and telephone.

It automatically controls the operation of the boiler, monitors its technical condition and signals when an accident occurs or the supply voltage is cut off.

Comfortable temperature:

Using ZONT H-1 GSM-Climate, you can remotely change the operating parameters of the heating system and control the room temperature. At the same time, it is possible to switch to the “Economy” or “Comfort” fixed temperature mode, create a weekly “Schedule” for the operation of the heating boiler, or turn it off remotely.
ZONT H-1 GSM-Climate independently monitors the readings of a digital air temperature sensor and adjusts the operation of the boiler depending on the specified temperature parameters in the room.

Remote control:

ZONT H-1 GSM-Climate is a compact device with its own SIM card, connected to a heating boiler. Commands can be sent to it from any phone (satellite, mobile or fixed line), tablet or PC. Remote control requires a unique password to prevent unauthorized access.

An additional “Alarm input” provides the connection of an unlimited number of similar detectors: motion or disconnection sensors, fire and smoke alarms, water leakage or gas leakage sensors and other similar equipment. Information is transmitted via mobile communications and the Internet. You simply indicate in the system settings the necessary telephone numbers for notification: yours or the security organization.

How does ZONT H-1 work in alarm mode?

Equipment selected depending on the task being solved is installed in the room, for example, sensors that respond to movement. Such sensors detect the presence of strangers in the house and send a signal to the unit’s GSM modem. An alarm notification is sent to programmed phone numbers in the form of a voice call or SMS message, and is also displayed in the personal account of the online service. Thus, you can quickly make a decision to protect your property: call the police or simply call your neighbors.

Of course, the main function of ZONT H-1 is to control the operation of the heating boiler. But you must admit that ensuring home security is a very useful feature of this “smart” device. Moreover, we are talking not only about protection from the penetration of unauthorized persons, but also from other risks: fire, water and gas leaks.That is, it is also a kind of insurance against everyday troubles.

Free WEB service:

  • Checking the health of an electric or gas boiler
  • Informing about an accident and loss of supply voltage
  • Controlling boiler operating modes from your phone and via the Internet
  • Indoor air temperature monitoring
  • Maintaining room temperature according to an individual schedule
  • Alerts about alarm input sensors (GSM alarm)
  • User-friendly interface and mobile applications for iOS and Android

Energy Saving:

If you are only at home on weekends or in the evening/night, the ZONT H-1 GSM-Climate control unit will maintain a minimum temperature in the house during your absence, saving energy resources, and when you return, it will create comfortable conditions in the house.

Functionality:

Free WEB interface:

  • constant connection with the server
  • recording and automatic transfer of accumulated information
  • display of boiler status:
    • current operating mode
    • room temperature
    • emergency mode indication
  • changing the boiler operating mode “in one click”
  • temperature monitoring for any period of time
  • weekly temperature schedule editor
  • notifications about activation of additional sensors (Alarm input)

Boiler operation control:

  • SMS commands
  • dialing to voice menu
  • through the Internet

Event Notification:

  • t change below the set threshold
  • t change above the set threshold
  • boiler accident
  • temperature sensor malfunction
  • loss and reappearance of supply voltage
  • triggering of “Alarm input” sensors

Event memory:

  • room temperature values ​​at any time
  • date and time of the boiler failure
  • date and time of change of operating mode
  • executed voice menu commands
  • sent SMS
  • date and time of software update
  • date and time of power on/off

Specifications:

Supply voltage 10-14 V
Maximum current consumption 150 mA
One analog input Yes
One dry contact output (make/break) Yes
Maximum current through relay contacts 1000 mA
Voice interface Yes
WEB interface Yes
1-Wire interface Yes
Operating temperature range from -30 to +55 °C
GSM modem frequency ranges 800, 900, 1800, 1900 MHz
GPRS data channel Yes
Backup battery BL-5C (optional) sold separately
Time to reach operating mode no more than 50 sec
dimensions 77 x 86 x 33 mm
Weight 200 gr
Housing material Plastic

Equipment:

  • Thermostat (Main unit of the system) - 1 pc.
  • Mounting base - 1 pc.
  • Digital temperature sensor - 1 pc.
  • Terminal block (2 pcs.) - 1 pc.
  • Network adapter 220/12 V - 1 pc.
  • GSM antenna - 1 pc.

Buy GSM thermostat Zont H-1V- means getting ownership of a compact thermostat with its own SIM card from any operator, which allows you to control the indoor climate from any phone (satellite, mobile or fixed line), tablet or PC. Most boilers have terminals closed with a jumper (corresponding to the boiler being on) for connecting a room thermostat. It is to these terminals that the Zont-H-1V modules are connected: this jumper is removed and the Zont H relay contacts are connected in its place.

The Micro Line company produces the Zont H-1V thermostat model, which is almost identical in functionality to the GSM Climate Zont H-1 thermostat, which differs only in different housings and some technical features:
- The relay in H-1V holds 220V, and in H-1 it is designed for 120V;
- Zont H-1V has a 220V->5V adapter for converting a high-voltage boiler alarm signal (available in Vaillant) into a low-voltage one for the Zont input;
- The backup battery in the H-1V module is built-in, but in the H-1 it is not included in the basic configuration and can be purchased separately;
- The firmware of these modules is exactly the same, and the circuits are almost the same.
- Attaches to DIN rail

Zont H1V will ensure economical consumption of fuel spent by the boiler for heating, will allow you to remotely set the temperature in the house and monitor the health of the heating boiler, as well as remotely control its operation!
Agree that manual control of heating devices is quite troublesome, and from a distance it is almost impossible. With the Zont H 1V unit, remote control of the heating system is not only possible, but also extremely simple and convenient! No matter how far from home you are, all you need to do is call or send a command from a mobile phone or via the Internet to change the heating boiler mode and ensure a comfortable temperature in the house. Convenient, isn't it?

New opportunities!

Additional functions of the device allow you not only to save heating costs and control the operation of the heating boiler, but also to monitor the safety of the facility! The user can connect additional sensors, for example, motion, disconnection, water leaks, gas leaks, fire and smoke sensors, etc. Information is transmitted via mobile communications and the Internet.

Features of the Zont H-1V thermostat

Supports various, preset temperature conditions:
Economy - economical fixed temperature.
Comfort - a comfortable fixed temperature (usually a few degrees higher than the economical temperature).
Schedule - maintaining the set temperature according to a schedule.
Off - anti-freeze mode
Alarm – thermostat operating mode when the temperature sensor is faulty.

The module will call only the owner’s phone or trusted numbers determined by him, warning him about all changes or emergency situations. Accordingly, Zont h-1v can only receive commands from the owner or from “its” phones. Unauthorized access is absolutely excluded - even if someone dialed the number by mistake, the device will ask for a password that only the owner and, for example, other family members or trusted persons know. In addition to SMS control, it is possible to control via the voice menu.
In fact, the Zont H-1V GSM module plays the role of your personal assistant - you called it, gave a command, for example, to heat it hotter in advance, and the whole family will eventually arrive in a warm and cozy home. Or vice versa: if you forgot to turn down the power in the morning when leaving for work - no problem, you can do it right from work, via the Internet.

Unlike competitors, the temperature cannot be controlled from the front panel, and all monitoring and control operations are performed using either a personal computer or mobile devices: a smartphone or tablet. This allows the owner to control the situation wherever he is, while significantly reducing the cost of the equipment.
The Zont-H1V unit works even when cellular communication is lost, executing, for example, a predetermined weekly schedule.
It is possible to use control commands in the form of SMS text and even using the voice menu.
A simple, functional and user-friendly graphical interface is used via a web browser or mobile application. All data is stored on the server and at any time you can view convenient and visual system operation graphs, information messages, or make the necessary settings.

New!

Weather-dependent automation - energy-efficient heating control taking into account changes in outside temperature (the function is available for modules with firmware version 122:74 and higher)

How does the Zont H1V thermostat control the boiler?

The thermostat measures the room temperature and turns the output relay on or off, controlling the boiler in heating mode so that the room temperature corresponds to the set value.
It controls the temperature in the house and outside, the supply voltage, the technical condition of the boiler and signals in the event of an accident or power failure. If the values ​​deviate from the specified ones, it informs the owner in any pre-selected way: call, SMS message or notification via the Internet.

To use the Internet service, you do not need to install additional software; work is carried out using any modern WEB browser. Access to the Internet service is provided through a personal page on the zont-online.ru server
From your personal account on the Internet service zont-online.ru, you need to set the desired indoor temperature values, as well as threshold levels for generating alarm messages when the temperature deviates to a critical (emergency) value.
The unit analyzes changes in indoor temperature using its own remote temperature sensor. Depending on the measurements taken, it turns on or off the output relay, which controls the operation of the boiler in heating mode so that the indoor temperature corresponds to the value of the set operating mode.
If a boiler malfunction occurs, the system will immediately notify the owner of this event, which will help avoid troubles.

Inputs, outputs and connected equipment

Thermal sensors (wired)
Connects to pins 4 and 6 of the thermostat in accordance with the proposed diagram. Up to 10 pieces can be connected at the same time. The distance of the latter in the loop is no more than 100 m. Long branches from the main loop can lead to the inoperability of all sensors.
Boiler control output
Contacts 1, 2 and 3 of the thermostat are intended for connection to the heating boiler. Contact No. 1 is common (O), contact No. 2 is normally closed (NC) and contact No. 3 (NO) is normally open. The device is connected to the boiler contacts intended for connecting the room thermostat.
GSM antenna
It is connected to a separate input and located indoors in such a way as to ensure the most stable reception of the GSM signal.
Main power + 12V
From a 220V network via a power supply (220/12V network adapter) included in the delivery set.
Backup power + 3.7V
From the built-in Li-ion battery.
Input 1 Analog input - pin No. 5.
Designed to connect: or security sensors; or “Boiler failure” signal; or room thermostat
Input 2 Digital input - pin No. 8.
Designed to connect: or security sensors; or “Boiler failure” signal; or room thermostat; or OpenTherm Interface and Radio Module ML-489.
Important!
You cannot simultaneously connect signals from an external room thermostat or “Boiler alarm” signals to both inputs.
You can simultaneously connect the OpenTherm Interface and the ML-489 Radio Module to Input 2

Functionality of GSM thermostat Zont H-1V

Remote control of the boiler operation can be carried out:
- SMS commands;
- when dialing a SIM card number using the voice menu;
- via the Internet (WEB interface and mobile applications for Android and iOS devices).

Convenient and simple WEB interface with the following capabilities:
- displaying the current state of the boiler and room temperature;
- boiler operation control;
- temperature monitoring (inside, outside the room, coolant) for any selected period of time;
- programming the boiler operation according to a schedule;
- notifications about the activation of additional sensors.

Various event alerts:
- when the measured temperature deviates from the specified threshold values;
- about a boiler failure (provided the thermostat is connected to the emergency output of the boiler);
- about a malfunction of the temperature sensor and the thermostat going into emergency mode;
- loss or restoration of power supply, in which case a backup battery is required;

The event log
- a diary of measured temperatures for any period without a statute of limitations;
- date and time of detection of the boiler failure;
- date and time of changing the operating mode of the boiler and thermostat;
- list of executed control commands via voice menu, transmitted by SMS, software updates;
- date and time of power failure or restoration.

Signaling about the status of additional sensors connected to the “Alarm” input of the thermostat;
Memorizing events:
- temperature sensor readings;
- date and time of the boiler accident;
- changes in operating modes;
- voice menu commands
- SMS commands;
- software updates;
- power on/off.
Update the current version of the unit’s firmware without turning it off and removing it from the user’s personal account.

Connection diagrams for Zont H1V thermostat

Scope of delivery Zont H-1V

Base unit: 1 piece
External GSM antenna: 1 pc.
Temperature sensor (digital, wired): 1 pc.
Power supply (network adapter) 220V/12V: 1 pc.
Boiler alarm signal converter 220/5V: 1 pc.
Instruction manual: 1 piece

Thermostat packaging

Technical characteristics of GSM thermostat Zont H-1V

Article: ML13213
Manufacturer: MicroLine (ordered by Evan)
Supply voltage: 10-28V
Maximum current consumption: 150 mA
Number of inputs: 2
Number of outputs (Type - dry contact, open/close): 1
Type of connected wired temperature sensors: DS 18S20
Type of connected radio thermal sensors: ML-703
Total number of simultaneously connected temperature sensors (wired and radio): 10
Maximum permissible cable length with temperature sensors: 100 m
Maximum current through relay contacts: 1000 mA
Maximum voltage of switched relay contacts: ~ 220 V, = 24 V
Voice interface: yes
WEB interface: yes
1-Wire interface: yes
Operating temperature range: from -30 to +55 °C
GSM modem frequency ranges: 800, 900, 1800, 1900 MHz
Data channel: GPRS
GSM antenna: external
Internal non-volatile memory: yes
Backup power: built-in Li-ion battery 103450-RSV-LD 2000 mAh
Time to reach operating mode: no more than 50 seconds
Average service life: 7 years
Overall dimensions, mm: 90 x 50 x 55
Weight, no more: 0.200 kg
Housing: plastic on DIN rail
Additional compatible Zont equipment: ML-489, ML-703, Zont Home, OpenTherm interface, Astra-9, Astra 512, Astra C, IO 102-16/2, Astra 361, ML-711, ML-712


Smart thermostat ZONT (ZONT models H-1, H-1V and H-2) is designed to meet the needs of vacation home users. The peculiarity of the situation is when there is no one in the house, but you need to be sure that the heating system is working. Moreover, the inertia of the heating system requires changing the boiler mode long before the owners arrive. All this can be solved with the help of our devices and Internet service. ZONT.

Features and principle of operation

Thermostat Feature ZONT-H is that it is focused on the use of the Internet. Now the main trend in this area is cloud service and this is exactly how the thermostat works. Unlike most competitors, it does not have a home control panel. All monitoring and control operations are performed using either a personal computer or mobile devices - a smartphone or tablet. This significantly reduces the cost of equipment, while at the same time allowing the user to control the situation wherever he is.

Thermostat ZONT - H It also works when the connection is lost, executing a predetermined program, for example, a weekly schedule. Additionally, it is possible to use control commands in the form of SMS text and even using the voice menu.

The user has the opportunity to use a very functional and powerful graphical interface through a web browser or mobile application. Convenient and visual graphics, information messages and settings are available. Data from the product is stored on the server and the user can view the entire history of events and parameters. The user interface is carefully designed and highly appreciated by numerous customers.

To meet the needs of different user groups, various models are produced, differing in the type of connection - GSM or WiFi. Structurally, some models are made in a small-sized case of their own design, others - in a standard case on a DIN rail for installation in an electrical cabinet.

The thermostat has 2 inputs for connecting various additional devices.
On Input 1 can be connected: or ; or with "Boiler failure" signal; or External room thermostat.

On Input 2 can be connected: or Security sensors and detectors; or with "Boiler failure" signal; or External room thermostat; or Interface OpenTherm And Radio module ML-489.

- Security sensors and detectors , connected to one input must be of the same type in connection method. Number of sensors in the loop - ICD, MKD, etc. no more than 10 pieces; water leak and gas leak detectors no more than 5 pcs. The maximum distance of the latter in the train is 100 m.

- WITH “Boiler failure” signal. To monitor the technical condition of the boiler and generate an alert about its emergency condition, the thermostat can be connected to the emergency output of the boiler.

- Room thermostat . By connecting an external room thermostat, it becomes possible to control the boiler either through ZONT-H 1 and through an external room thermostat, the choice of how control is carried out is made remotely via the Internet service or SMS command "Manual mode".

When operating from an external thermostat, remote monitoring of the room temperature and all alert modes (accidents, power loss/restoration, alarm events, etc.) will be maintained.

- Radio module ML-489. Thermostat interface module ZONT with radio devices It provides reception and relaying of information from radio devices to the ZONT server

For boilers that have a computerized OpenTherm interface There is an adapter that allows you to expand control and monitoring functions and ensure fuel savings through advanced system operation algorithms.

How to choose and operate thermostats correctly ZONT?

Models ZONT H-1 and ZONT H-1V have a GSM communication channel and are designed for very little Internet traffic. Therefore, the price of the subscription fee to the mobile operator is minimal

The ZONT H-2 model has a WiFi communication channel and is used where a wireless local network already exists.

1. Internet traffic is about 60 MB per month*

*indicated taking into account rounding to 100kb per hour

It is important to take into account that the actual consumption of Internet traffic highly depends on the nature of the device’s use and the quality of the connection. Accordingly, the worse the connection conditions, the more often the device reconnects to the server, and the more traffic is consumed.

To make the subscription fee easily predictable, we recommend choosing tariffs with unlimited traffic.

Many operators offer tariffs in which the Internet speed drops when a certain limit is reached. Such tariffs are also good because ZONT devices do not have special requirements for connection speed.

If you choose a tariff with per-megabyte payment for traffic, then pay attention to the amount of traffic rounding. With a large rounding value (for example, more than 100 KB), the operator may count many times more traffic than the device actually consumes. The smaller the rounding size, the better.

2. Calls and SMS

ZONT devices use voice calls and SMS messages only for alarm notification, therefore, choose a tariff based on the expected number of alerts.

Attention! There are tariffs that are incompatible with work ZONTA

  • From November 2015 on MTS Smart tariffsInternet operation is blocked in 3G modems . Along with modems, the operator also blocks our devices.
  • Option "Tablet XS" from MegaFonDesigned for use on tablets only , and in ZONT devices it either does not work at all or leads to constant loss of communication.

Important!

Flashing is an extremely desirable step when you first turn it on. The fact is that in production the product receives the current firmware, and the user prefers to have the latest one. So we recommend that you reflash the thermostat before using it.

Flashing should be carried out under user control. Since the communication channel is usually unreliable, you need to make sure that the flashing procedure is successful and the product is connected again.

Video about ZONT H1V:

YouTube Video

How to set up a power outage alert

Settings - thermostat settings - input No. 2 - "panic button"
- - emergency input polarity - "ground fault"
- -alerts-alarming events-"your phone"-"envelope"
-save

Instead of "input 2" you can also use "input 1". For ZONT-H1V it’s basically the same, just different contacts.

The difference between ZONT H-1V and ZONT H-1 is as follows:

  • the relay in H-1V holds 220V. The relay in H-1 is rated for 120V;
  • ZONT H-1V has a 220V->5V adapter for converting a high-voltage boiler alarm signal (available in Vaillant) into a low-voltage one for the ZONT input;
  • relays have opposite logic - the information is outdated, it corresponds to products manufactured before xxx 2015 (see the section “connection to the boiler”):
    • ZONT H-1 - the boiler heats up when the relay is energized. If the power is lost, the relay turns off. The internal battery does not power the relay, so it does not help turn the relay on. Therefore, when planning the system layout, you need to take this into account, for example, power the Umbrella and the boiler from the same UPS;
    • ZONT H-1V - the boiler heats up when the relay is de-energized. Therefore, if the power goes out, the relay turns off, but the boiler turns on with the relay contacts. The umbrella can be hung without a UPS, it will know about a power failure and send an SMS about it;
  • The battery in the H-1V is built-in, while in the H-1 it is not even included in the basic kit. It can be purchased in addition;
  • and most importantly, the firmware of both options is the same. Schemes, almost the same. Different cases;

Connection to the WAMOS QX boiler (EVAN)

(This scheme is not suitable for other Evan boilers)

The umbrella, wanting to turn on the boiler, closes 1-3, opens 1-2.

The boiler has an IN input. Although it is called the air temperature sensor input, we use it as the thermostat input. You can use another, alternative input - a heated floor sensor. They are essentially the same.

The ZONT H1 relay is connected as follows. The central contact of the relay (1) is connected to the IN input. The normally closed relay contact (2) is connected to the “-” input. The normally open relay contact (3) is connected to the “+” input.

To make it clear, the “+” and “-” contacts of the boiler are connected to the 5V power circuit. As a result, the ZONT H1 relay switches them to the IN input.

Test of the first start-up of the boiler, using the example of EVAN WARMOS QX

  1. Set the set temperature lower than in the room. Make sure that the boiler inlet is ZERO. The boiler should not heat;
  2. Set the set temperature higher than in the room. Make sure that the boiler input is +5V. Actually, the boiler must heat the water, and without a multimeter it will be clear that the pipe is getting hotter and hotter.

Thermal sensor

All sensors are connected in parallel. The web interface has a procedure for assigning a “own name” to each sensor.

Please note that there are many modifications of these sensors on the market and they differ in discreteness. The product comes with a DS18S20 sensor with a resolution of 0.1 degrees. Sometimes users buy sensors externally. Therefore, we provide additional information on different types of sensors:

  • DS1820 is an old, discontinued model. It differs from all new models in its elongated body. It has a capacity of 9 bits, which leads to a discreteness of 0.5 degrees;
  • DS18 S 20 - Has a capacity of 12 bits, recommended for use. Note that manufacturers label the microcircuit as DS1820, so it can only be distinguished by the size of the case, it is shorter;
  • DS18 B 20 - Has a different operating protocol. The ZONT H1 program supports 12 bits for it, that is, a discreteness of 0.1 degrees;

If you already have a room thermostat and want to include ZONT - H in the gap between the boiler and the room thermostat?

Yes, now it is possible. To do this, you need to connect the room thermostat to one of the thermostat inputsZONT.

This connection allows you to control the boiler remotely (via ZONT ) and manually, according to commands from this room thermostat. The choice of control method is carried out via the Internet service or SMS command "Manual mode".

When operating from a room thermostat, remote temperature monitoring and all alert modes are maintained (about an accident, power loss/restoration, alarm events, etc.).

Many people are interested in how the discrete inputs of ZONT H are made?

  • Input 2 - may have options:
  • Input 1 - may have options:

Relay contacts

Relay diagram:


It can be seen that when the power is turned off, contacts 1 and 2 are closed. This must be taken into account, keeping in mind the situation with power failure. The boiler usually turns off when the control contacts open and turns on when they close. But there are also opposite options!! Then an external relay is required, which inverts the operating logic. This relay is switched on by the ZONT H contacts.

Often ZONT H is turned on together with the boiler via an Uninterruptible Power Supply (UPS).

First steps to turn on the GSM thermostat ZONT H

  1. Preparation and setup
    1. Buy a SIM card (standard size, no micro- or nano-SIM) and top up its balance. Minimum requirement - 5-10 MB and 10 SMS (while you play with the settings, you’ll just spend it);
    2. Before using it in the product, it is better if you already have a personal account set up on the telecom operator’s website. It will help you see the dynamics of money and traffic consumption and solve emerging problems.
    3. Have a suitable place where you record and save accounts and passwords. You will need to do this for your SIM card personal account, for the ZONT web interface, and for the access password from your phone. It's amazing how often we forget passwords :-)
    4. Before connecting the device to the boiler, set it up “on the table”:
      1. Register yourself on the sitehttps://zont-online.ru/
      2. Register the device on the same website - there is a “add device” sign there.
      3. Install the SIM card (open the receiving clip, fold it up, insert the SIM card into the slots with the cut corner up, soldering the SIM card to the contacts)
      4. Connect the included antenna (there is no internal antenna, so this is required). Please note that if the room is in the basement or in an area of ​​poor reception, then the antenna should be placed as high as possible
      5. Connect the temperature sensor and power supply (AC adapter).
      6. < > Dial an SMS in your phone about resetting to factory settings. There are a lot of letters, and the time for sending will be limited, so we advise you to type the text in advance. Don't send SMS yet.
      7. < This item is optional. Needed if there is no web interface> Enter the SMS text into your phone about the registration of your phone. There are a lot of letters, and the time for sending will be limited, so we advise you to type the text in advance. WITHwrite serial number small letters and what needs to be done after the serial number space and be sure to write the word " Telephone ", and write the number without any hyphens between the numbers. Do not send an SMS yet.
      8. Connect the connectors and apply power
      9. Wait for one of two options for a green signal on the device:
        1. so that it lights up constantly and sometimes goes out for a split second several times in a row (indicates that there is a network and the signal level is normal). This is an option when there is both a GSM connection and a connection to the server;
        2. so that it flashes in a series of flashes, at least two flashes, with a pause between flashes.This is an option when the GSM connection is established, but there is no connection to the server. In this case, SMS can be used.
      10. EIf the green indicator flashes only once for a short time, it means there is no GSM connection and there is no point in sending SMS.
      11. < This item is optional. Required if the SIM card is NOT a MEGAFON or the device was released before September 2015> Send an SMS with the APN access point setting. How to do this is written in the instructions.
      12. Log in to the web interface and wait for the device to appear connected. After this, you can add a phone number for voice and SMS notifications in the web interface settings. If this is done, then there is no need to send an SMS with the same number. That is, paragraph 14 is not required.
      13. <This item is optional. Most likely, it will be required if the procedure is repeated. If for some reason the first pass didn’t work out>Send SMS about factory reset.After resetting to factory settings, you will need to remove the device from the list and add it again.
      14. <This item is optional. Needed if there is no web interface>Send SMS about the registration of your phone. Wait for the response message “phone number has been established.”
  2. Before connecting to the boiler
    1. Try to find out the type of connection (normally closed or normally open), it depends on which contacts on the block the wire from the boiler is connected to. To do this, you need to study the documentation for the boiler. You can simulate it by connecting a jumper and make sure that the boiler reacts correctly
    2. Install the device and sensors permanently
  3. Connection
    1. Connect the wires from the boiler
    2. Change modes and monitor the boiler’s reaction
    3. As soon as the boiler begins to respond adequately to the control input, you can begin setting up modes

Battery backup and UPS

The backup battery in the ZONT thermostat is intended only to notify the server and owner via SMS about the loss of the main 220V power supply. Usually the boiler cannot operate without main power, so there is no point in controlling the boiler in this situation.

Sometimes the user installs a UPS - an uninterruptible power supply. It connects to the boiler and it is logical to power ZONT from it. But a problem arises: ZONT does not recognize the loss of the main 220V power supply. In this case, you can select “Boiler emergency” for notification. You can buy any cheap power supply or charger with an output voltage of 5V and connect it to this input. The circuit, unfortunately, requires a couple more parts - a resistor (any) and a diode (any):


Configure Input 2 in the web interface to the "ground fault" mode.

Some UPSs have a main power failure output. Then you just need to connect it to Input 2 and select one of the “Input Polarity” options - “open” or “short”.

It is important to add that SMS and web notifications will be sent not only when an accident occurs, but also when it disappears.

Color of the temperature sensor wires included in the delivery kit

The two-strand wire used is misleading to some. It’s worth taking a closer look; let’s call the one that’s “more red” “red.” The one that is “blacker” will be called “black”. If it's completely unclear, don't be afraid. Turn it on at random and if the sensor works, you will see the readings in the web interface. You can heat one in order to distinguish between several connected in parallel.

How often is data sent to the server?

Sensor readings are sent to the server once a minute. Emerging events (exceeding permissible limits, etc.) - immediately upon occurrence.

Some unimportant parameters (information about balance, GSM signal level, etc.) are sent upon request from the server. The server sends requests for this data once every minute or two, but only if the user is online in the ver-interface or mobile application.

If the web interface does not sense user activity for 10 minutes, it goes into “sleep mode”. In this mode, the web interface stops updating data from the server as you move the mouse. Temperature and event data continues to be sent to the server in real time.

Explanations for setting Input 1

General comment. On the "Status" tab, the "Security" button appears for the options "motion sensor", "motion sensor with delay", "short-to-minus sensor", "minus-opening sensor". This button can be turned on or off, that is, you can make the input active or disabled.

For other options, the "Security" button is absent, that is, the input is considered to be constantly active.

  • "not used" - should be selected if it is not connected. Otherwise, you may get an alarm
  • "delayed motion sensor" - triggered when the circuit opens. There is a delay of 30 seconds. The web interface displays the message "motion detected"
  • "motion sensor without delay" - triggered when the circuit opens. The web interface displays the message "motion detected"
  • "water leakage sensor" - an analog input is used, triggered at a voltage less than 2.4V. The web interface displays the message "water leakage detected"
  • "gas leak sensor" - triggered when the circuit opens to ground. The web interface displays the message "gas leak".
  • "alarm button
  • "short circuit to negative sensor" - triggered when there is a ground fault
  • The ZONT H-1V thermostat model has a 220VAC relay, but also limited current.

Buy Zont H-1 GSM-Climate- means getting ownership of a compact thermostat with its own SIM card from any operator, which allows you to control the indoor climate from any phone (satellite, mobile or fixed line), tablet or PC. Manufactured by Micro Line specifically for the Russian manufacturer of heating boilers Evan.

Zont H1 GSM-Climate will ensure economical consumption of fuel spent by the boiler for heating, will allow you to remotely set the temperature in the house and monitor the proper operation of the heating boiler, as well as remotely control its operation!
Agree that manual control of heating devices is quite troublesome, and from a distance it is almost impossible. With the Zont H 1 unit, remote control of the heating system is not only possible, but also extremely simple and convenient! No matter how far from home you are, all you need to do is call or send a command from a mobile phone or via the Internet to change the heating boiler mode and ensure a comfortable temperature in the house. Convenient, isn't it?

New opportunities!

Additional functions of the device allow you not only to save heating costs and control the operation of the heating boiler, but also to monitor the safety of the facility! The user can connect additional sensors, for example, motion, disconnection, water leaks, gas leaks, fire and smoke sensors, etc. Information is transmitted via mobile communications and the Internet.

Features of Zont H-1 GSM-Climate

Supports various preset temperature modes:
Economy - economical fixed temperature.
Comfort - a comfortable fixed temperature (usually a few degrees higher than the economical temperature).
Schedule - maintaining the set temperature according to a schedule.
Off - anti-freeze mode
Alarm – thermostat operating mode when the temperature sensor is faulty.

The module will call only the owner’s phone or trusted numbers determined by him, warning him about all changes or emergency situations. Accordingly, Zont GSM-Climate can receive commands only from the owner or from “its” phones. Unauthorized access is absolutely excluded - even if someone dialed the number by mistake, the device will ask for a password that only the owner and, for example, other family members or trusted persons know. In addition to SMS control, it is possible to control via the voice menu.
In fact, the GSM Climate Zont H1 module acts as your personal assistant - you called it, gave a command, for example, to heat it hotter in advance, and the whole family will eventually arrive in a warm and cozy home. Or vice versa: if you forgot to turn down the power in the morning when leaving for work - no problem, you can do it right from work, via the Internet.

Unlike competitors, it does not have a control panel and all monitoring and control operations are performed using either a personal computer or mobile devices: a smartphone or tablet, which allows the owner to control the situation wherever he is, while significantly reducing the cost of the equipment.
The Zont-H1 unit works even when cellular communication is lost, executing, for example, a predetermined weekly schedule.
It is possible to use control commands in the form of SMS text and even using the voice menu.
A simple, functional and user-friendly graphical interface is used via a web browser or mobile application. All data is stored on the server and at any time you can view convenient and visual system operation graphs, information messages, or make the necessary settings.
Most boilers have terminals closed with a jumper (corresponding to the boiler being on) for connecting a room thermostat. It is to these terminals that the Zont-H modules are connected: this jumper is removed and the Zont H relay contacts are connected in its place.

New!

Weather-dependent automation - energy-efficient heating control taking into account changes in outside temperature (the function is available for modules with firmware version 122:74 and higher)

How does the GSM-Climate thermostat control the boiler?

The thermostat measures the room temperature and turns the output relay on or off, controlling the boiler in heating mode so that the room temperature corresponds to the set value.
It controls the temperature in the house and outside, the supply voltage, the technical condition of the boiler and signals in the event of an accident or power failure. If the values ​​deviate from the specified ones, it informs the owner in any pre-selected way: call, SMS message or notification via the Internet.

To use the Internet service, you do not need to install additional software; work is carried out using any modern WEB browser. Access to the Internet service is provided through a personal page on the zont-online.ru server
From your personal account on the Internet service zont-online.ru, you need to set the desired indoor temperature values, as well as threshold levels for generating alarm messages when the temperature deviates to a critical (emergency) value.
The unit analyzes changes in indoor temperature using its own remote temperature sensor. Depending on the measurements taken, it turns on or off the output relay, which controls the operation of the boiler in heating mode so that the indoor temperature corresponds to the value of the set operating mode.
If a boiler malfunction occurs, the system will immediately notify the owner of this event, which will help avoid troubles.

Functionality of the GSM thermostat Zont H-1 GSM-Climate

Remote control of the boiler operation can be carried out:
- SMS commands;
- when dialing a SIM card number using the voice menu;
- via the Internet (WEB interface and mobile applications for Android and iOS devices).

Convenient and simple WEB interface with the following capabilities:
- displaying the current state of the boiler and room temperature;
- boiler operation control;
- temperature monitoring (inside, outside the room, coolant) for any selected period of time;
- programming the boiler operation according to a schedule;
- notifications about the activation of additional sensors.

Various event alerts:
- when the measured temperature deviates from the specified threshold values;
- about a boiler failure (provided the thermostat is connected to the emergency output of the boiler);
- about a malfunction of the temperature sensor and the thermostat going into emergency mode;
- loss or restoration of power supply, in which case a backup battery is required;

The event log
- a diary of measured temperatures for any period without a statute of limitations;
- date and time of detection of the boiler failure;
- date and time of changing the operating mode of the boiler and thermostat;
- list of executed control commands via voice menu, transmitted by SMS, software updates;
- date and time of power failure or restoration.

Signaling about the status of additional sensors connected to the “Alarm” input of the thermostat;
Memorizing events:
- temperature sensor readings;
- date and time of the boiler accident;
- changes in operating modes;
- voice menu commands
- SMS commands;
- software updates;
- power on/off.
Update the current version of the unit’s firmware without turning it off and removing it from the user’s personal account.

Connection diagrams for the Zont H-1 GSM-Climate thermostat

Scope of delivery Zont H-1 GSM-Climate

Thermostat
Mounting base
Digital temperature sensor
Terminal blocks (2 pcs.)
Network adapter 220/12 V.
External GSM antenna
Passport
Backup battery (optional)

Technical characteristics of the Zont H-1 GSM-Climate thermostat

Article: 112005 (Evan), ML12074 (Micro Line)
Manufacturer: Micro Line (ordered by Evan)
Supply voltage, volts: 10 - 28
Maximum current consumption, mA: 150
One analog input
One dry contact output (make/break)
Maximum voltage of switched relay contacts: AC. 120 V DC 24 V
Maximum current through relay contacts, mA: 1000
Adjustable hysteresis, °C: +/-0.1 - 2
Voice interface: yes
WEB interface: yes
1-Wire interface: yes
Operating temperature range, °C: from -30 to +55
GSM modem frequency ranges, MHz: 800, 900, 1800, 1900
GPRS data channel: yes
External GSM antenna: yes
Internal non-volatile memory: yes
Time to reach operating mode, sec: no more than 50
Overall dimensions, mm: 77 x 86 x 33
Weight, grams: 200
High-strength plastic housing
Additional compatible Zont equipment: ML-489, ML-703, Zont Home, OpenTherm interface, Astra-9, Astra 512, Astra C, IO 102-16/2, Astra 361, ML-711, ML-712

GSM-Climate ZONT H-1 - heating boiler remote control unit

  • Control of an electric or gas boiler from the phone and via the Internet;
  • Notification about the activation of security sensors (GSM alarm);
  • Installation in a convenient location;
  • Controls the temperature in the house;
  • Saves heating resources;
  • Maintains comfortable temperature conditions;
  • Warns of a boiler failure;
  • Informs about penetration into the premises;
  • The maximum number of sensors is 5;
  • Recommended for self-installation.

Among other things, Micro Line has developed applications for Android and iOS, through which you can control your heating boiler from anywhere in the world.

An intelligent GSM thermostat will control your boiler so that it will heat your home only when it is really needed, maintaining a comfortable temperature in the house according to an individual schedule.

By logging into the application, you can not only find out the temperature in the room, but also set the boiler to preset modes, turn it on according to a schedule, or simply turn off the boiler.

Attention! For correct operation of the GSM module on the territory of the Autonomous Republic of Crimea, a SIM card from the mobile operator “Volna Mobile” is required.
Today, Volna Mobile provides mobile data services in 2G, 3G, 4G standards throughout the Republic of Crimea and Sevastopol.

Control your comfort from your phone, tablet or computer

ZONT H-1 is a room thermostat with its own SIM card, connected to a heating boiler. Commands can be sent to it from any phone, tablet or PC.

For ease of use, there are free phone applications and a personal account on the website. To protect against unauthorized access, access to your personal account is password protected.

Individual setting of operating modes

Comfortable temperature is different for everyone. Some people love tropical heat, others believe that 20-22 degrees is more than enough.

We have provided several home heating modes so that you can select the one you need at the moment in one move.

In addition, you can easily create a weekly operating schedule for your heating boiler for the most optimal consumption of electricity or gas.

Safe boiler operation and comfortable temperature

The thermostat measures the room temperature and turns the output relay on or off, controlling the operation of the boiler so that the room temperature corresponds to the set value.

It monitors the technical condition of the boiler and signals in case of an accident or power outage.

Alert system for all occasions

The thermostat controls the temperature in the house and outside, supply voltage, technical condition of the boiler and much more.

If the values ​​deviate from the specified ones, it informs you about this by call or SMS message.

10 temperature sensors for any purpose.

You can simultaneously connect 10 temperature sensors to the thermostat. These can be either wired or radio sensors.

The main readings are used to control the operation of the boiler. An additional one is assigned to his reserve. If the main thermostat malfunctions, it automatically switches to operation using the backup sensor and control of the boiler does not stop.

The readings of the remaining sensors are used for general monitoring of the heating system.

Easy installation, no special skills required

ZONT H-1 easily connects to an electric or gas boiler instead of a room thermostat. A SIM card of any operator that provides stable reception is inserted into it, and the supply voltage is supplied. You need to send an SMS to the SIM card number from the owner’s phone and “introduce” the devices.

There is no need to pay to use the device

Pay only the actual costs of communication between you and the thermostat according to the tariffs of the selected operator. And no subscription fee!

On which boilers can a ZONT thermostat be installed?

ZONT, ​​in its main purpose, is a simple room thermostat, but only implemented on a hardware platform using a GSM/GPRS modem and WEB technology.

The principle of its operation and the method of connection to any gas or electric boiler is exactly the same as that of conventional thermostats. It connects to the connector for the room regulator and controls the boiler, maintaining the set temperature according to the readings of its temperature sensor. To do this, the thermostat turns the boiler on or off by closing the contacts of its output relay.

Thus, if your boiler provides the ability to control commands from a room thermostat, then the ZONT thermostat can be used with it.

Supply voltage 10-28V
Maximum current consumption 150 mA
Number of analog inputs 1
Output dry contact (make/open) 1
Type of connected wired temperature sensors DS 18S20
Type of connected radio thermal sensors ML-703
Total number of simultaneously connected temperature sensors 10
Maximum permissible length of cable with temperature sensors 100 m
Maximum current through relay contacts 1000 mA
Maximum voltage of switched relay contacts ~ 120 V, = 24 V
Voice interface There is
WEB interface There is
1-Wire interface There is
Operating temperature range from -30 to +55 °C
GSM modem frequency ranges 800, 900, 1800, 1900 MHz
Data link GPRS
GSM antenna external
Internal non-volatile memory There is
Built-in battery backup Li-ion / 1000 mA*N (optional)
Time to reach operating mode no more than 50 sec
Average service life 7 years
dimensions 77 x 86 x 33 mm
Weight, no more 0.200 kg
Housing material ABC plastic

Equipment data